No edit summary |
No edit summary |
||
Line 15: | Line 15: | ||
!'''Feed rate override''' <small>(2.4.1+)</small> | !'''Feed rate override''' <small>(2.4.1+)</small> | ||
!'''Rapid override''' <small>(2.8.8+)</small> | !'''Rapid override''' <small>(2.8.8+)</small> | ||
!'''Cutting time''' <small>(2.8.21+)</small> | |||
!'''Minimum proxy version''' | !'''Minimum proxy version''' | ||
|- | |- | ||
Line 27: | Line 28: | ||
|✓ | |✓ | ||
|✓ | |✓ | ||
| | |||
| | | | ||
|2.8.18 | |2.8.18 | ||
Line 41: | Line 43: | ||
|✔ | |✔ | ||
|✔ | |✔ | ||
| | |||
|2.8.10 | |2.8.10 | ||
|- | |- | ||
Line 54: | Line 57: | ||
|✔ | |✔ | ||
|✔ | |✔ | ||
| | |||
|2.0.0 | |2.0.0 | ||
|- | |- | ||
Line 65: | Line 69: | ||
| | | | ||
|✓ | |✓ | ||
| | |||
| | | | ||
| | | | ||
Line 79: | Line 84: | ||
|✓ | |✓ | ||
|✓ | |✓ | ||
| | |||
|2.8.3 | |2.8.3 | ||
|- | |- | ||
Line 89: | Line 95: | ||
| | | | ||
|✓ | |✓ | ||
| | |||
| | | | ||
| | | | ||
Line 103: | Line 110: | ||
|✓ | |✓ | ||
|✓<sup>4</sup> | |✓<sup>4</sup> | ||
|✓ | |||
|✓ | |✓ | ||
|✓ | |✓ | ||
Line 118: | Line 126: | ||
|✓ | |✓ | ||
|✓ | |✓ | ||
| | |||
|2.8.12 | |2.8.12 | ||
|- | |- | ||
Line 125: | Line 134: | ||
|✓ | |✓ | ||
|✓ | |✓ | ||
| | |||
| | | | ||
| | | | ||
Line 144: | Line 154: | ||
|✓ | |✓ | ||
| | | | ||
|✓ | |||
|1.0.0 | |1.0.0 | ||
|- | |- | ||
|[[Siemens SINUMERIK]] 840D sl | |[[Siemens SINUMERIK]]840D sl | ||
|OPC-UA | |OPC-UA | ||
|✓ | |✓ | ||
Line 157: | Line 168: | ||
|✓ | |✓ | ||
|✓ | |✓ | ||
| | |||
|2.7.6 | |2.7.6 | ||
|- | |- | ||
Line 170: | Line 182: | ||
|✓ | |✓ | ||
| | | | ||
|✓ | |||
|2.8.11 | |2.8.11 | ||
|- | |- | ||
Line 182: | Line 195: | ||
| | | | ||
|✓ | |✓ | ||
| | |||
| | | | ||
|2.7.8 | |2.7.8 | ||
Line 187: | Line 201: | ||
|[[XMC OnTakt Integration|XMC]]<sup>5</sup> | |[[XMC OnTakt Integration|XMC]]<sup>5</sup> | ||
|TCP | |TCP | ||
|✓ | |||
|✓ | |✓ | ||
|✓ | |✓ | ||
Line 232: | Line 247: | ||
!'''Feed rate override''' | !'''Feed rate override''' | ||
!'''Rapid override''' | !'''Rapid override''' | ||
!'''Cutting time''' | |||
|- | |- | ||
|DMG MORI | |DMG MORI | ||
Line 244: | Line 260: | ||
|✔ | |✔ | ||
|✔ | |✔ | ||
| | |||
|- | |- | ||
|Makino Hyper-i | |Makino Hyper-i | ||
Line 255: | Line 272: | ||
|✓ | |✓ | ||
|✓ | |✓ | ||
| | |||
| | | | ||
|- | |- | ||
Line 268: | Line 286: | ||
|✓ | |✓ | ||
|✓ | |✓ | ||
| | |||
|} | |} | ||
[[Category:OnTakt User Guide]] | [[Category:OnTakt User Guide]] | ||
{{DEFAULTSORT:Machine_Support}} | {{DEFAULTSORT:Machine_Support}} |
Revision as of 13:36, 14 March 2025
Unless noted otherwise, version numbers on this page refer to the OnTakt Proxy. See the OnTakt Changelog for release dates.
Currently available
This table is also displayed on the OnTakt Machine Setup page.
Model | Protocol | Cycle state | Part count | Program name | Emergency stop | Variables | Alarms | Active tool (2.7.11+) | Feed rate override (2.4.1+) | Rapid override (2.8.8+) | Cutting time (2.8.21+) | Minimum proxy version |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Brother | OPC-UA | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | 2.8.18 | ||
DMG MORI | MTConnect | ✔ | ✔ | ✔ | ✓ | ✓ | ✔ | ✔ | 2.8.10 | |||
FANUC | FOCAS2 | ✔ | ✔ | ✔ | ✔ | ✔1 | ✔ | ✔ | ✔ | ✔ | 2.0.0 | |
Haas NGC | Ethernet Q Commands | ✓ | ✓ | ✓ | ✓1 | ✓ | 2.0.1 | |||||
MTConnect | ✓ | ✓ | ✓ | ✓ | ✓2 | ✓2 | ✓3 | ✓ | ✓ | 2.8.3 | ||
Keyence MD-X | WebMonitor | ✓ | ✓ | ✓ | 2.0.1 | |||||||
Mazak MAZATROL | MTConnect | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓4 | ✓ | ✓ | ✓ | 2.6.4 |
Caron MiConnect | REST API | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | 2.8.12 | |||
OctoPrint | REST API | ✓ | ✓ | ✓ | 2.5.0 | |||||||
Okuma OSP | MTConnect | ✓ | ✓ | ✓ | ✓ | ✔ | ✓ | ✔ | ✓ | ✓ | 1.0.0 | |
Siemens SINUMERIK840D sl | OPC-UA | ✓ | ✓ | ✓ | ✓ | ✓1 | ✓ | ✓ | ✓ | ✓ | 2.7.6 | |
Sodick EDM | MTConnect | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | 2.8.11 | |||
TRUMPF TruLaser | OPC-UA | ✓ | ✓ | ✓ | ✓ | ✓ | 2.7.8 | |||||
XMC5 | TCP | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | 2.7.3 |
✓ indicates single-path support
✔ indicates multi-path support (requires proxy version 2.8.0 or newer)
1 Only variables used in OnTakt are read from the control, including but not limited to:
- Program load variable
- Machine part count variable
- Process part count variable
- Process display variable
- Process mapped variables
2 Requires the control to have software version 100.20.000.1200 or newer.[source]
3 Requires some additional configuration.
4 MAZATROL controls must have MTConnect schema version 1.4 or newer to report the active tool.
5 Features available on machines connected via XMC may vary by machine type, software versions, and configuration.
Coming soon
Model | Protocol | Cycle state | Part count | Program name | Emergency stop | Variables | Alarms | Active tool | Feed rate override | Rapid override | Cutting time |
---|---|---|---|---|---|---|---|---|---|---|---|
DMG MORI | OPC-UA | ✔ | ✓ | ✔ | ✓ | ✓ | ✔ | ✔ | ✔ | ||
Makino Hyper-i | OPC-UA | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | |||
HEIDENHAIN HeROS (TNC 640 & TNC 7) | OPC-UA | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |