No edit summary |
No edit summary |
||
Line 11: | Line 11: | ||
!'''Variables''' | !'''Variables''' | ||
!'''Feed rate override''' | !'''Feed rate override''' | ||
!'''Rapid override< | !'''Rapid override'''<small>(proxy 2.8.8+)</small> | ||
!'''Active tool< | !'''Active tool'''<small>(proxy 2.7.11+)</small> | ||
!'''Minimum proxy version''' | !'''Minimum proxy version''' | ||
|- | |- | ||
Line 73: | Line 73: | ||
|✓ | |✓ | ||
|✓<sup>2</sup> | |✓<sup>2</sup> | ||
|✓<sup>2</sup> | |✓<sup>2,3</sup> | ||
|✓ | |✓ | ||
|✓ | |✓ | ||
Line 102: | Line 102: | ||
|✓ | |✓ | ||
|✓ | |✓ | ||
|✓<sup> | |✓<sup>4</sup> | ||
|2.6.4 | |2.6.4 | ||
|- | |- | ||
Line 209: | Line 209: | ||
<small><sup>2</sup> Haas controls must have software version 100.20.000.1200 or newer for full MTConnect functionality.<sup>[https://www.haascnc.com/service/troubleshooting-and-how-to/how-to/machine-data-collection---ngc.html#MT-Connect <nowiki>[source]</nowiki>]</sup></small> | <small><sup>2</sup> Haas controls must have software version 100.20.000.1200 or newer for full MTConnect functionality.<sup>[https://www.haascnc.com/service/troubleshooting-and-how-to/how-to/machine-data-collection---ngc.html#MT-Connect <nowiki>[source]</nowiki>]</sup></small> | ||
<small><sup>3</sup> | <small><sup>3</sup> Requires [[Haas NGC#Active tool reporting|additional configuration]].</small> | ||
<small><sup> | <small><sup>4</sup> MAZATROL controls must have MTConnect schema version 1.4 or newer to report the active tool.</small></onlyinclude> | ||
</onlyinclude> | |||
== Coming soon == | == Coming soon == |
Revision as of 16:39, 12 March 2025
Currently available
This table is also displayed on the OnTakt Machine Setup page.
Model | Protocol | Cycle state | Part count | Emergency stop | Program name | Alarms | Variables | Feed rate override | Rapid override(proxy 2.8.8+) | Active tool(proxy 2.7.11+) | Minimum proxy version |
---|---|---|---|---|---|---|---|---|---|---|---|
Brother | OPC-UA | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | 2.8.18 | |
DMG MORI | MTConnect | ✔ | ✔ | ✓ | ✔ | ✓ | ✔ | ✔ | 2.8.10 | ||
FANUC | FOCAS2 | ✔ | ✔ | ✔ | ✔ | ✔ | ✔1 | ✔ | ✔ | ✔ | 2.0.0 |
Haas NGC | Ethernet Q Commands | ✓ | ✓ | ✓ | ✓1 | ✓ | 2.0.1 | ||||
MTConnect | ✓ | ✓ | ✓ | ✓ | ✓2 | ✓2,3 | ✓ | ✓ | ✓ | 2.8.3 | |
Keyence MD-X | WebMonitor | ✓ | ✓ | ✓ | 2.0.1 | ||||||
Mazak MAZATROL | MTConnect | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓4 | 2.6.4 |
Caron MiConnect | REST API | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | 2.8.12 | ||
OctoPrint | REST API | ✓ | ✓ | ✓ | 2.5.0 | ||||||
Okuma OSP | MTConnect | ✓ | ✓ | ✓ | ✓ | ✓ | ✔ | ✓ | ✔ | 1.0.0 | |
Siemens SINUMERIK 840D sl | OPC-UA | ✓ | ✓ | ✓ | ✓ | ✓ | ✓1 | ✓ | ✓ | ✓ | 2.7.6 |
Sodick EDM | MTConnect | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | 2.8.11 | |||
TRUMPF TruLaser | OPC-UA | ✓ | ✓ | ✓ | ✓ | ✓ | 2.7.8 | ||||
XMC | TCP | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | 2.7.3 |
✓ indicates single-path support
✔ indicates multi-path support (requires proxy version 2.8.0 or newer)
1 Only variables used in OnTakt are read from the control, including but not limited to:
- Program load variable
- Machine part count variable
- Process part count variable
- Process display variable
- Process mapped variables
2 Haas controls must have software version 100.20.000.1200 or newer for full MTConnect functionality.[source]
3 Requires additional configuration.
4 MAZATROL controls must have MTConnect schema version 1.4 or newer to report the active tool.
Coming soon
Model | Protocol | Cycle state | Part count | Emergency stop | Program name | Alarms | Variables | Feed rate override | Rapid override5 | Active tool4 | Minimum proxy version |
---|---|---|---|---|---|---|---|---|---|---|---|
DMG MORI | OPC-UA | ✔ | ✓ | ✓ | ✔ | ✓ | ✔ | ✔ | ✔ | 2.8.11 | |
Makino Hyper-i | OPC-UA | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ | 2.8.21 | ||
HEIDENHAIN HeROS (TNC 640 & TNC 7) | OPC-UA | ✓ | ✓ | ✓ | ✓ | ✓ | ✓ |