OnTakt Machine Compatibility: Difference between revisions

From Knowledge Base
No edit summary
No edit summary
Line 1: Line 1:
== Currently available ==
<onlyinclude>
<onlyinclude>
{| class="wikitable"
{| class="wikitable"
Line 27: Line 28:
|2.8.18
|2.8.18
|-
|-
| rowspan="2" |DMG MORI
|DMG MORI
|[[MTConnect (DMG MORI)|MTConnect]]
|[[MTConnect (DMG MORI)|MTConnect]]
|✔
|✔
Line 39: Line 40:
|
|
|2.8.10
|2.8.10
|-
|OPC-UA
|✔
|✓
|✓
|✔
|✓
|
|✔
|✔
|✔
|2.8.11
|-
|-
|[[FANUC]]
|[[FANUC]]
Line 155: Line 144:
|1.0.0
|1.0.0
|-
|-
|[[Siemens SINUMERIK]]
|[[Siemens SINUMERIK]] 840D sl
|OPC-UA
|OPC-UA
|✓
|✓
Line 226: Line 215:
<small><sup>5</sup></small> <small>Reading the rapid override requires proxy version 2.8.8 or newer.</small>
<small><sup>5</sup></small> <small>Reading the rapid override requires proxy version 2.8.8 or newer.</small>
</onlyinclude>
</onlyinclude>
== Coming soon ==
{| class="wikitable"
!'''Model'''
!'''Protocol'''
!'''Cycle state'''
!'''Part count'''
!'''Emergency stop'''
!'''Program name'''
!'''Alarms'''
!'''Variables'''
!'''Feed rate override'''
!'''Rapid override<sup>5</sup>'''
!'''Active tool<sup>4</sup>'''
!'''Minimum proxy version'''
|-
|DMG MORI
|OPC-UA
|✔
|✓
|✓
|✔
|✓
|
|✔
|✔
|✔
|2.8.11
|-
|Makino Hyper-i
|OPC-UA
|✓
|
|✓
|✓
|✓
|✓
|✓
|
|✓
|2.8.21
|-
|HEIDENHAIN HeROS (TNC 640 & TNC 7)
|OPC-UA
|✓
|
|
|✓
|✓
|
|✓
|✓
|✓
|
|}
[[Category:OnTakt User Guide]]
[[Category:OnTakt User Guide]]
{{DEFAULTSORT:Machine_Support}}
{{DEFAULTSORT:Machine_Support}}

Revision as of 15:54, 12 March 2025

Currently available

Model Protocol Cycle state Part count Emergency stop Program name Alarms Variables Feed rate override Rapid override5 Active tool4 Minimum proxy version
Brother OPC-UA 2.8.18
DMG MORI MTConnect 2.8.10
FANUC FOCAS2 1 2.0.0
Haas NGC Ethernet Q Commands 1 2.0.1
MTConnect 2 2 2.8.3
Keyence MD-X WebMonitor 2.0.1
Mazak MAZATROL MTConnect 3 2.6.4
Caron MiConnect REST API 2.8.12
OctoPrint REST API 2.5.0
Okuma OSP MTConnect 1.0.0
Siemens SINUMERIK 840D sl OPC-UA 1 2.7.6
Sodick EDM MTConnect 2.8.11
TRUMPF TruLaser OPC-UA 2.7.8
XMC TCP 2.7.3

✓ indicates single-path support

✔ indicates multi-path support (requires proxy version 2.8.0 or newer)

1 Only variables used in OnTakt are read from the control, including but not limited to:

  • Program load variable
  • Machine part count variable
  • Process part count variable
  • Process display variable
  • Process mapped variables

2 Haas controls must have software version 100.20.000.1200 or newer for full MTConnect functionality.[source]

3 MAZATROL controls must have MTConnect schema version 1.4 or newer to report the active tool.

4 Reading the active tool requires proxy version 2.7.11 or newer.

5 Reading the rapid override requires proxy version 2.8.8 or newer.


Coming soon

Model Protocol Cycle state Part count Emergency stop Program name Alarms Variables Feed rate override Rapid override5 Active tool4 Minimum proxy version
DMG MORI OPC-UA 2.8.11
Makino Hyper-i OPC-UA 2.8.21
HEIDENHAIN HeROS (TNC 640 & TNC 7) OPC-UA