(Created page with "To set up communication with a FANUC control, see FANUC FOCAS. ==Part counting== Bit #0 of parameter 6700 determines which M-codes will cause the part counter (stored in parameter 6711) to increment. *If it is set to 0: <code>M02</code>, <code>M30</code>, and <code>MX</code> (where X is the value of parameter 6710) will increment the part counter. *If it is set to 1: Only <code>MX</code> (where X is the value of parameter 6710) will increment the part counter. Par...") |
No edit summary |
||
Line 5: | Line 5: | ||
*If it is set to 0: <code>M02</code>, <code>M30</code>, and <code>MX</code> (where X is the value of parameter 6710) will increment the part counter. | *If it is set to 0: <code>M02</code>, <code>M30</code>, and <code>MX</code> (where X is the value of parameter 6710) will increment the part counter. | ||
*If it is set to 1: Only <code> | *If it is set to 1: Only <code>M''x''</code> (where ''x'' is the value of parameter 6710) will increment the part counter. | ||
Parameter 6710 holds the M-code to use for part counting as described above. | Parameter 6710 holds the M-code to use for part counting as described above. | ||
Line 13: | Line 13: | ||
{| class="wikitable" | {| class="wikitable" | ||
|+Behavior of parameters 6700 and 6710 | |+Behavior of parameters 6700 and 6710 | ||
!6700 | !6700#0 | ||
!6710 | !6710 | ||
!Behavior | !Behavior | ||
Line 22: | Line 22: | ||
|- | |- | ||
|0 | |0 | ||
|x > 0 | |''x'' > 0 | ||
|<code>M02</code>, <code>M30</code>, and <code> | |<code>M02</code>, <code>M30</code>, and <code>M''x''</code> count parts | ||
|- | |- | ||
|1 | |1 | ||
Line 30: | Line 30: | ||
|- | |- | ||
|1 | |1 | ||
|x > 0 | |''x'' > 0 | ||
|Only <code> | |Only <code>M''x''</code> counts parts | ||
|} | |} | ||
[[Category:OnTakt User Guide]] |
Revision as of 12:38, 10 April 2023
To set up communication with a FANUC control, see FANUC FOCAS.
Part counting
Bit #0 of parameter 6700 determines which M-codes will cause the part counter (stored in parameter 6711) to increment.
- If it is set to 0:
M02
,M30
, andMX
(where X is the value of parameter 6710) will increment the part counter. - If it is set to 1: Only
Mx
(where x is the value of parameter 6710) will increment the part counter.
Parameter 6710 holds the M-code to use for part counting as described above.
- If it is set to 0, it will not be used at all.
6700#0 | 6710 | Behavior |
---|---|---|
0 | 0 | M02 and M30 count parts
|
0 | x > 0 | M02 , M30 , and Mx count parts
|
1 | 0 | Part counting is disabled |
1 | x > 0 | Only Mx counts parts
|