Revision as of 11:39, 10 April 2023
To set up communication with a FANUC control, see FANUC FOCAS.
Part counting
Bit #0 of parameter 6700 determines which M-codes will cause the part counter (stored in parameter 6711) to increment.
- If it is set to 0:
M02
,M30
, andMx
(where x is the value of parameter 6710) will increment the part counter. - If it is set to 1: Only
Mx
(where x is the value of parameter 6710) will increment the part counter.
Parameter 6710 holds the M-code to use for part counting as described above.
- If it is set to 0, it will not be used at all.
6700#0 | 6710 | Behavior |
---|---|---|
0 | 0 | M02 and M30 count parts
|
0 | x > 0 | M02 , M30 , and Mx count parts
|
1 | 0 | Part counting is disabled |
1 | x > 0 | Only Mx counts parts
|