Siemens SINUMERIK

From Knowledge Base
Revision as of 15:28, 5 September 2023 by Andy (talk | contribs)

Control configuration

Enabling the OPC-UA server

  1. Press the MENU SELECT key.
  2. Switch to the the Setup interface at the bottom of the screen.
    Setup softkey.webp
  3. Press the softkey page button at the bottom right of the screen.
    Softkey switcher.webp
  4. Open the Licenses softkey.webp window.
  5. License all options.webp
    Switch to the "All options" tab at the top right.
  6. Press the Search > button to the right of the screen.
  7. Enter "OPC" in the search field. Search opc.webp
  8. Press OK at the bottom right of the screen.
  9. When "Access MyMachine / OPC UA" is highlighted, press the Cancel button at the bottom right of the screen.
    Search result.webp
  10. Check the "Set" box for the option if it is not already checked and then press the Back button at the bottom right.
    OPC-UA enabled.webp
  11. If the option was not already enabled, restart the control.

Configuring the OPC-UA server

...

OnTakt configuration

...