Revision as of 15:04, 5 September 2023 by Andy (talk | contribs) (Created page with "== Control configuration == === Enabling the OPC-UA server === # Press the MENU SELECT key. # Switch to the the Setup interface at the bottom of the screen. # Press the softkey page button at the bottom right of the screen. # Open the Licenses window. # Switch to the "All options" tab at the top right. # Press the Search button to the right of the screen. # Enter "OPC" in the search field. # Press OK at the bottom right of the screen. # When "Access MyMachine / OPC UA"...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

Control configuration

Enabling the OPC-UA server

  1. Press the MENU SELECT key.
  2. Switch to the the Setup interface at the bottom of the screen.
  3. Press the softkey page button at the bottom right of the screen.
  4. Open the Licenses window.
  5. Switch to the "All options" tab at the top right.
  6. Press the Search button to the right of the screen.
  7. Enter "OPC" in the search field.
  8. Press OK at the bottom right of the screen.
  9. When "Access MyMachine / OPC UA" is highlighted, press the Cancel button at the bottom right of the screen.
  10. Check the "Set" box for the option if it is not already checked and then press the Back button at the bottom right.
  11. If the option was not already enabled, restart the control.

Configuring the OPC-UA server

...

OnTakt configuration

...