Revision as of 15:04, 5 September 2023 by Andy (talk | contribs) (Created page with "== Control configuration == === Enabling the OPC-UA server === # Press the MENU SELECT key. # Switch to the the Setup interface at the bottom of the screen. # Press the softkey page button at the bottom right of the screen. # Open the Licenses window. # Switch to the "All options" tab at the top right. # Press the Search button to the right of the screen. # Enter "OPC" in the search field. # Press OK at the bottom right of the screen. # When "Access MyMachine / OPC UA"...")
Control configuration
Enabling the OPC-UA server
- Press the MENU SELECT key.
- Switch to the the Setup interface at the bottom of the screen.
- Press the softkey page button at the bottom right of the screen.
- Open the Licenses window.
- Switch to the "All options" tab at the top right.
- Press the Search button to the right of the screen.
- Enter "OPC" in the search field.
- Press OK at the bottom right of the screen.
- When "Access MyMachine / OPC UA" is highlighted, press the Cancel button at the bottom right of the screen.
- Check the "Set" box for the option if it is not already checked and then press the Back button at the bottom right.
- If the option was not already enabled, restart the control.
Configuring the OPC-UA server
...
OnTakt configuration
...