(Created page with "== OPC-UA == The following controls support OPC-UA: {| class="wikitable" !Control !Minimum NC software version |- |TNC7 |81762x-16 |- |TNC7 basic |81762x-18 |- |TNC 640 |34059x-10 |- |TNC 620 |81760x-08 |} == LSV2 == The following controls support LSV2: * TNC 406 * TNC 407 * TNC 415/B * TNC 425 * TNC 426.A/.B<sup>1</sup> * TNC 430.A<sup>1</sup> * iTNC 530 <small><sup>1</sup> Minimum NC software version: 280 462 05, 280 470 01, 280 472 01</small>") |
(→LSV2) |
||
Line 28: | Line 28: | ||
* TNC 430.A<sup>1</sup> | * TNC 430.A<sup>1</sup> | ||
* iTNC 530 | * iTNC 530 | ||
Other controls may support LSV2 in a limited capacity. | |||
<small><sup>1</sup> Minimum NC software version: 280 462 05, 280 470 01, 280 472 01</small> | <small><sup>1</sup> Minimum NC software version: 280 462 05, 280 470 01, 280 472 01</small> |
Revision as of 18:05, 3 April 2025
OPC-UA
The following controls support OPC-UA:
Control | Minimum NC software version |
---|---|
TNC7 | 81762x-16 |
TNC7 basic | 81762x-18 |
TNC 640 | 34059x-10 |
TNC 620 | 81760x-08 |
LSV2
The following controls support LSV2:
- TNC 406
- TNC 407
- TNC 415/B
- TNC 425
- TNC 426.A/.B1
- TNC 430.A1
- iTNC 530
Other controls may support LSV2 in a limited capacity.
1 Minimum NC software version: 280 462 05, 280 470 01, 280 472 01