No edit summary |
No edit summary |
||
Line 5: | Line 5: | ||
# Press the [[File:MENU SELECT.webp|alt=MENU SELECT]] key. | # Press the [[File:MENU SELECT.webp|alt=MENU SELECT]] key. | ||
# Switch to the the Setup interface at the bottom of the screen. [[File:Setup_softkey.webp|none|frame]] | # Switch to the the Setup interface at the bottom of the screen. [[File:Setup_softkey.webp|none|frame]] | ||
# Press the softkey page button at the bottom right of the screen. [[File:Softkey_switcher.webp|frame| | # Press the softkey page button at the bottom right of the screen. [[File:Softkey_switcher.webp|frame|none]] | ||
# Open the [[File:Licenses softkey.webp]] window. | # Open the [[File:Licenses softkey.webp]] window. | ||
# Switch to the "All options" tab at the top right.[[File:License_all_options.webp|none|frame]] | # Switch to the "All options" tab at the top right.[[File:License_all_options.webp|none|frame]] |
Revision as of 15:44, 5 September 2023
Control configuration
Enabling the OPC-UA server
- Press the key.
- Switch to the the Setup interface at the bottom of the screen.
- Press the softkey page button at the bottom right of the screen.
- Open the window.
- Switch to the "All options" tab at the top right.
- Press the button to the right of the screen.
- Enter "OPC" in the search field.
- Press at the bottom right of the screen.
- When "Access MyMachine / OPC UA" is highlighted, press the Cancel button at the bottom right of the screen.
- Check the "Set" box for the option if it is not already checked and then press the Back button at the bottom right.
- If the option was not already enabled, restart the control.
Configuring the OPC-UA server
TK
OnTakt configuration
Set the following options in the machine setup area:
- System: OPC-UA
- Model: SINUMERIK 840D sl
- NC URL:
opc.tcp://IP
, whereIP
is the IP address of the control. - NC authentication:
username:password
, whereusername
andpassword
are the OPC-UA username and password configured in the OPC-UA settings on the control.