No edit summary |
No edit summary |
||
Line 7: | Line 7: | ||
# Press the softkey page button at the bottom right of the screen. [[File:Softkey_switcher.webp|none|frame]] | # Press the softkey page button at the bottom right of the screen. [[File:Softkey_switcher.webp|none|frame]] | ||
# Open the [[File:Licenses softkey.webp]] window. | # Open the [[File:Licenses softkey.webp]] window. | ||
# Switch to the "All options" tab at the top right. | # Switch to the "All options" tab at the top right.[[File:License_all_options.webp|none|frame]] | ||
# Press the [[File:Button search.webp|alt=Search >]] button to the right of the screen. | |||
# Enter "OPC" in the search field. [[File:Search_opc.webp|none|frame]] | # Enter "OPC" in the search field. [[File:Search_opc.webp|none|frame]] | ||
# Press [[File:Button ok.webp|alt=OK]] at the bottom right of the screen. | # Press [[File:Button ok.webp|alt=OK]] at the bottom right of the screen. | ||
Line 16: | Line 16: | ||
=== Configuring the OPC-UA server === | === Configuring the OPC-UA server === | ||
TK | |||
== OnTakt configuration == | == OnTakt configuration == | ||
... | Set the following options in the machine setup area: | ||
* '''System:''' OPC-UA | |||
* '''Model:''' SINUMERIK 840D sl | |||
* '''NC URL:''' <code>opc.tcp://IP</code>, where <code>IP</code> is the IP address of the control. | |||
* '''NC authentication:''' <code>username:password</code>, where <code>username</code> and <code>password</code> are the OPC-UA username and password configured in the OPC-UA settings on the control. | |||
[[Category:OnTakt User Guide]] | [[Category:OnTakt User Guide]] |
Revision as of 15:33, 5 September 2023
Control configuration
Enabling the OPC-UA server
- Press the key.
- Switch to the the Setup interface at the bottom of the screen.
- Press the softkey page button at the bottom right of the screen.
- Open the window.
- Switch to the "All options" tab at the top right.
- Press the button to the right of the screen.
- Enter "OPC" in the search field.
- Press at the bottom right of the screen.
- When "Access MyMachine / OPC UA" is highlighted, press the Cancel button at the bottom right of the screen.
- Check the "Set" box for the option if it is not already checked and then press the Back button at the bottom right.
- If the option was not already enabled, restart the control.
Configuring the OPC-UA server
TK
OnTakt configuration
Set the following options in the machine setup area:
- System: OPC-UA
- Model: SINUMERIK 840D sl
- NC URL:
opc.tcp://IP
, whereIP
is the IP address of the control. - NC authentication:
username:password
, whereusername
andpassword
are the OPC-UA username and password configured in the OPC-UA settings on the control.