13 August 2024

13 June 2024

21 May 2024

  • curprev 16:1616:16, 21 May 2024Andy talk contribs 705 bytes +705 Created page with "== Part counting == Okuma OSP controls have 4 "work counters" (A, B, C, and D) that all increment when a program calls M02 or M30. OnTakt reads the work counter configured in the Okuma MTConnect adapter settings on the control. === Manually setting the part counter === The work counters can be adjusted from MDI or part programs by using the VWKCC system variables: * <code>VWKCC[1]</code> (work counter A) * <code>VWKCC[2]</code> (work counter B) * <code>VWKCC[3]</code>..." Tag: Visual edit